Project Capability

GAS TRAIN
     

Prepiped And Customised Gas Trains:

  • We  offers Gas Trains in Standard and Custom Configuration and Construction. Since, The Gas Trains is the essential Part of Gas Burner Safety, We offers  Gas Train on line of NFPA 86 Burner & Boiler Safety Regulations. Pre-Piped and Pre-Tested Gas Trains are tremendous Time and Effort savers and are made to be as easy as Plug & Play.
  • Gas Trains are available for almost all Gaseous Fuels like LPG, Natural Gas, Propane, Biogas and Clean Producer / BF Gas.
  • Most of the MADAS Gas Train Components are ATEX approved for Installation in Zone 2 & 22, Group II 3G & II 3D.
  • Product versions for Installation in Zone 1 & 21, Group II 2G & 2D also available.
  • All Gas Trains are tested for Leakages, Flows and Components requiring setting are accurately set to the Set points.
  • A Prewired Junction Box is available as option, which facilitates the Wiring of all Electrical Devices on Gas Train at a Single Terminal Strip. Various configurations available as per Customer and Combustion System Requirement, including Flow meters and Control Valves.
  • Inlet Connections from DN25 to DN150
  • Outlet Connections from DN25 to DN200Inlet Pressure ratings from 0.5 Bar to 5 Bar

Customised Gas Trains:

We can also offer Customised Gas Trains based on User’s requirements after carefully studying the requirements of the combustion process at the customer’s plant.

Various aspects like Space availability, User’s Control Logic, Burner consumption, Configurations are studied jointly with User and a suitable solution is offered to meet the requirement.

Straight Design Prepiped Gas Trains:

We offer Standard Straight Design Prepiped Gas Trains  as a standalone product to the user.

Specifications :-

  • Train type : Single/Multiple Burner
  • Service : LPG/Natural Gas/ Propane / If other specify Gas Combustion
  • Sizes :  DN15 to DN100 (Higher Sizes on request)
  • Inlet Gas Pressure : Upto 5 Bar (Higher Inlet request)
  • Piping : MS SH40 Seamless ( Other piping on request)
  • Flow Measurement : Optional On Request
  • Mounting : MS structural Mounting skid
  • Clamping : Tube Clamps
  • Prewired junction Boxes provided on request

Information Required:

  • Gas to be used
  • Pipeline size
  • Max Inlet Pressure (bar)
  • Outlet Pressure range (mBar)
  • Max . Gas flow (Nm3/hr)
  • Power Supply/Control Voltage : (V ac/ V dc)
  • No. of Burners : Single/Multiple.

 

Loop Design Prepiped Gas Trains:

       We offer Standard Straight Design Prepiped Gas Trains at as a standalone product to the user.
     These are most suitable in applications where the installation space is limited in length and where the no

 Of Safety and Control Instruments on the Gas Train are more.

Specifications :-           

Train type : Single/Multiple Burner

Service : LPG/Natural Gas/ Propane / If other specify Gas Combustion

Sizes:  DN15 to DN100 (Higher Sizes on request)

Inlet Gas Pressure: Up to 5 Bar (Higher Inlet request)

Piping : MS SH40 Seamless Optional On Request

Mounting : MS structural Mounting skid

 Clamping : Tube Clamp

  Prewired junction Boxes provided on request

Information Required:

  • Gas to be used
  • Pipeline size
  • Max Inlet Pressure (bar)
  • Outlet Pressure range (mBar)
  • Max . Gas flow (Nm3/hr)
  • Power Supply/Control Voltage : (V ac/ V dc)
  • No.of Burners : Single/Multiple